MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE FIFTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE THIRD TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FOURTH TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SECOND TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SIXTH TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.693 INCHES MAXIMUM ALL FLANGES |
AHSY | FLANGE INSIDE HEIGHT | 0.319 INCHES MINIMUM AND 0.323 INCHES MAXIMUM ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.358 INCHES MINIMUM AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM AND 0.255 INCHES MAXIMUM ALL FLANGES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL ALL FLANGES SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.143 INCHES MINIMUM AND 0.149 INCHES MAXIMUM ALL FLANGES FIRST CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.65 |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.791 INCHES NOMINAL |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.693 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.323 INCHES MAXIMUM |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.421 INCHES NOMINAL |
CSPL | WAVEGUIDE LONGER OFFSET DISTANCE | 41.580 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE ALL FLANGES SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE ALL FLANGES FIRST CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE ALL FLANGES |
FEAT | SPECIAL FEATURES | BOTH FLANGES PRESSURIZED; 1ST W/ RF/PRESSURE SEAL AND FOUR 0.625 IN. LG SCREWS; 2ND W/ FOUR 1.000 IN. LG SCREWS |
FLEX | FLEXIBILITY | FLEXIBLE FIFTH TUBING SEGMENT |
FLEX | FLEXIBILITY | FLEXIBLE FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | FLEXIBLE THIRD TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FOURTH TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID SIXTH TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY FOURTH TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY SECOND TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY SIXTH TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY FIFTH TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY FIRST TUBING SEGMENT |
MATT | MATERIAL | COPPER ALLOY THIRD TUBING SEGMENT |
MATT | MATERIAL | RUBBER CHLOROPRENE OR RUBBER SILICONE ALL TUBING JACKET |
SFTT | SURFACE TREATMENT | ENAMEL ALL FLANGE OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL FOURTH TUBING SEGMENT OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL SECOND TUBING SEGMENT OUTSIDE SURFACES |
SFTT | SURFACE TREATMENT | ENAMEL SIXTH TUBING SEGMENT OUTSIDE SURFACES |
STYL | STYLE DESIGNATOR | BEND TYPE |
SUPP | SUPPLEMENTARY FEATURES | ONE END MARKED W/ARROW AND LETTERS FWD; INCLUDES FOUR MTG FLANGES |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |